Penentuan diagnostik reference level (drl) lokal proyeksi thorax pa pada modalitas radiografi umum villa s.m di instalasi radiologi rsi unisma malang

  • Amatullah Al Auliaa UIN Malang

Abstract

DRL (Diagnostic Reference Level) is a tool to estimate the appropriate dose without harming the patient. This study aims to determine the local DRL value in Pa thorax examination at RSI Unisma Malang. Determination of the local DRL value based on INAK and ESAK parameters, the DRL value is obtained from the second quartile of INAK and ESAK values. The results obtained from this research show that the local DRL value of the INAK parameter is 0.12 mGy and the local DRL value calculated from the ESAK parameter is 0.16 mGy. From these results, it can be said that the dose received by patients at the thorax examination at RSI Unisma Malang has complied with the BAPETEN standard.

Downloads

Download data is not yet available.

References

Badan, K. (2012). Kepala badan pengawas tenaga nuklir republik indonesia.

BAPETEN, P. K. N. (9 C.E.). Tahun 2011 Tentang Uji Kesesuaian pesawat Sinar-X Radiologi Diagnostik dan Intervensional.

BAPETEN. (2019). Pedoman Teknis Penyusunan Tingkat Panduan Diagnostik Atau Diagnostic Reference Level (DRL) Nasional.

Delves, D. (2007). International Atomic Energy Agency. IAEA safety glossary: terminology used in nuclear safety and radiation protection. 2007. Vienna: International Atomic Energy Agency, 227.

Elnahwi, H. M., & Buhmeida, A. (2013). Evaluation of Survivin Expression in Renal Cell Carcinoma by Immunohistochemistry and Studying its Correlation with Clinicopathological Features and Prognosis (Doctoral dissertation, University of Benghazi).

Faradina Pratiwi, R., Pulungan, E. S., Andini, D., & Pratiwi, R. F. (n.d.). PENGARUH FAKTOR EKSPOSI TERHADAP KUALITAS CITRA RADIOGRAFI PADA PEMERIKSAAN THORAX.

Irsal, M., Targian, A., Elisa Wulandari, S., & Kinasih, N. (2023). Evaluasi Diagnostic Reference Levels (DRL) Pada Pemeriksaan Thorax PA di Pulau Jawa Berdasarkan Database DRL BAPETEN. Jurnal Pengawasan Tenaga Nuklir, 3(2), 88–96. https://doi.org/10.53862/jupeten.v3i2.014

Jurnal, P. :, Masyarakat, K., Yani, A., & Kesehatan, B. P. (2018). PEMANFAATAN TEKNOLOGI DALAM BIDANG KESEHATAN MASYARAKAT UTILIZATION OF TECHNOLOGY IN THE HEALTH OF COMMUNITY HEALTH. Artikel XII, 8(1). http://jurnal.unismuhpalu.ac.id/index.php/PJKM

Monita, R. M. R. (2021). Analisis Penerapan Keselamatan Radiasi Sinar-X Pada Pekerja Radiasi Di Instalasi Radiologi Rumah Sakit Pekanbaru Medical Center (Pmc) Tahun 2020. Media Kesmas (Public Health Media), 1(1), 26–39.

Putra, I. K., Ratnawati, G. A. A., & Sutapa, G. N. (2021). General radiographic patient dose monitoring using conformity test data. Int. Res. J. Eng. IT Sci. Res, 7(6), 219–224.

PlumX Metrics

Published
2024-12-06
How to Cite
Auliaa, A. (2024). Penentuan diagnostik reference level (drl) lokal proyeksi thorax pa pada modalitas radiografi umum villa s.m di instalasi radiologi rsi unisma malang. Maliki Interdisciplinary Journal, 2(11), 545-550. Retrieved from https://urj.uin-malang.ac.id/index.php/mij/article/view/11847
Section
Articles