Penentuan diagnostik reference level (drl) lokal proyeksi thorax pa pada modalitas radiografi umum villa s.m di instalasi radiologi rsi unisma malang
Abstract
DRL (Diagnostic Reference Level) is a tool to estimate the appropriate dose without harming the patient. This study aims to determine the local DRL value in Pa thorax examination at RSI Unisma Malang. Determination of the local DRL value based on INAK and ESAK parameters, the DRL value is obtained from the second quartile of INAK and ESAK values. The results obtained from this research show that the local DRL value of the INAK parameter is 0.12 mGy and the local DRL value calculated from the ESAK parameter is 0.16 mGy. From these results, it can be said that the dose received by patients at the thorax examination at RSI Unisma Malang has complied with the BAPETEN standard.
Downloads
References
Badan, K. (2012). Kepala badan pengawas tenaga nuklir republik indonesia.
BAPETEN, P. K. N. (9 C.E.). Tahun 2011 Tentang Uji Kesesuaian pesawat Sinar-X Radiologi Diagnostik dan Intervensional.
BAPETEN. (2019). Pedoman Teknis Penyusunan Tingkat Panduan Diagnostik Atau Diagnostic Reference Level (DRL) Nasional.
Delves, D. (2007). International Atomic Energy Agency. IAEA safety glossary: terminology used in nuclear safety and radiation protection. 2007. Vienna: International Atomic Energy Agency, 227.
Elnahwi, H. M., & Buhmeida, A. (2013). Evaluation of Survivin Expression in Renal Cell Carcinoma by Immunohistochemistry and Studying its Correlation with Clinicopathological Features and Prognosis (Doctoral dissertation, University of Benghazi).
Faradina Pratiwi, R., Pulungan, E. S., Andini, D., & Pratiwi, R. F. (n.d.). PENGARUH FAKTOR EKSPOSI TERHADAP KUALITAS CITRA RADIOGRAFI PADA PEMERIKSAAN THORAX.
Irsal, M., Targian, A., Elisa Wulandari, S., & Kinasih, N. (2023). Evaluasi Diagnostic Reference Levels (DRL) Pada Pemeriksaan Thorax PA di Pulau Jawa Berdasarkan Database DRL BAPETEN. Jurnal Pengawasan Tenaga Nuklir, 3(2), 88–96. https://doi.org/10.53862/jupeten.v3i2.014
Jurnal, P. :, Masyarakat, K., Yani, A., & Kesehatan, B. P. (2018). PEMANFAATAN TEKNOLOGI DALAM BIDANG KESEHATAN MASYARAKAT UTILIZATION OF TECHNOLOGY IN THE HEALTH OF COMMUNITY HEALTH. Artikel XII, 8(1). http://jurnal.unismuhpalu.ac.id/index.php/PJKM
Monita, R. M. R. (2021). Analisis Penerapan Keselamatan Radiasi Sinar-X Pada Pekerja Radiasi Di Instalasi Radiologi Rumah Sakit Pekanbaru Medical Center (Pmc) Tahun 2020. Media Kesmas (Public Health Media), 1(1), 26–39.
Putra, I. K., Ratnawati, G. A. A., & Sutapa, G. N. (2021). General radiographic patient dose monitoring using conformity test data. Int. Res. J. Eng. IT Sci. Res, 7(6), 219–224.
Copyright (c) 2024 Amatullah Al Auliaa

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work’s authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal’s published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.



